If you want to reset TR515/TR510

For Ethernet interface type, follow the steps as below.

  1. Connect TR515/TR510 with Hub via WAS-1499 cable.
  2. Power on TR515/TR510.
  3. Disable the firewall and antivirus program in your computer!
  4. Use “Change IP” function of the software DS Manager to set an available IP address for TR515/TR510.
  5. Open the software TR515 Tool/TR510 Tool.
  6. Enter the IP address you have set at the step (4).
    tr51x_04_10_01.jpg
  7. Double click [000-Default]. Once the connection is successful, the firmware version message will appear in [Status] box.
    tr51x_04_10_02.jpg
  8. Click [Reset].
    tr51x_04_10_03.jpg
  9. Click [Yes].
    tr51x_04_10_04.jpg
  10. Click [OK].
    tr51x_04_10_05.jpg
  11. Power off TR515/TR510.
  12. Power on TR515/TR510. The message “In It” will be shown on the display of TR515/TR510 when processing the reset. OnceTR515/TR510 sounds a long beep and two short beeps and its display shows the time, it indicates the reset is completed.

For RS232 interface type, follow the steps as below.

  1. Connect TR515/TR510 with your computer via RS232 cable.
  2. Power on TR515/TR510.
  3. Set Comm. Port.
    tr51x_04_10_06.jpg
  4. Follow the steps (7)~(12) described in “For Ethernet interface type” part as above.